TOP PERKIN ELMER AUTOSAMPLER SECRETS

Top perkin elmer autosampler Secrets

Top perkin elmer autosampler Secrets

Blog Article

Mixing by aspiration—mixing of sample by aspiration instead of shaking guarantees homogeneity with the sample and maintains cell viability

The CytKick Max Autosample contains a Improve mode that permits speedier sample processing, and also passive cooling for some plates/racks. A CytKick Max Accent Kit is bundled which contains four accent plates: two cooling plates and two tube adaptors, as well as a Max dongle vital. A computer is just not incorporated Using the autosampler because a person is provided with the cytometer.

To prevent probe crashes, which can need highly-priced probe substitute, the CytKick Max Autosampler automatically performs a probe self-calibration that can help make sure reliable positioning from the probe within just each very well. The self-calibration verifies correct purpose of the probe, lowers variability in probe positioning over time to avoid failures all through plate runs, and aids make improvements to reliability above the lifetime of the procedure.

In contrast to other plate loaders that mix samples by shaking, which may not guarantee homogeneity of your sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing whilst preserving sample viability and resulting in regular facts with CVs less than 10% across the plate. The CytKick Max Autosampler also has a gentle mix mode for fragile cell lines.

The autosampler’s indicator lights and warning devices are actually designed to make certain that a consumer that has walked from the technique can easily see the technique standing constantly.

To keep up program versatility, the manual sample probe is often obtainable even though the loader is current, and switching in between tubes and plates is detected by way of computer software and will not need additional person intervention.

The CytKick Max Autosampler was meant to limit procedure down time. Automatic sampling devices are often tormented by clogging or probe crashes. The Intelligent Probe, by using a two hundred-micron diameter that is certainly greater than most probes obtainable during the industry, minimizes circumstances of clogging.

The intuitive software program makes it possible for rapid Mastering and facts Examination. By way of example, a heat map watch lets fast screening and affirmation of samples while the instrument is getting details.

Effortless transition—no disassembly, no further QC, no reboot required for conversion amongst plates and tubes

The CytKick Max Autosampler has two options for processing samples in a significant-throughput environment: high-throughput method and Improve manner.

Self-calibration from the probe also makes it possible for the autosampler being quickly moved, so it can be shared among a number of devices.

The instrument design and computer software were produced with shopper relieve-of-use in your mind. The CytKick Max Autosampler has fluidic bottles with sensors that advise the person in the event the fluids need to get replaced.

Autocleaning of autosampler is finished in the course of the instrument shutdown system as a result no more person methods are demanded to maintain technique.

Starting an experiment While using pe autosampler the Attune NxT cytometric application is straightforward. Using a plate format check out, people can produce compensation wells, define instrument options, and detect samples.

Report this page